HPDC platform Status: Engineered on request

Application · Megawatt charging

Power electronics for megawatt charging and DC fast charging

Electric trucks, buses, ships and construction machines charge with power in the megawatt range. knestronX supplies the power stage for this from 250 kW SiC modules, galvanically isolated and connectable in series or parallel. We are looking for charging applications with special requirements for environment or input voltage.

DC source rectifier, storage, DC grid
650–800 VDC
BRW isolation
TSB series/parallel
charging voltage
Vehicle truck, bus, ship

Typical topology: balancer + BRW + 2L-TSB. Input 650–750 VDC (800 VDC optional), with balancer up to 1500 VDC.

250 kW

per module

Multi-MW

by combining modules

±700 A

per module in parallel

1400 VDC

per module in series

The task

Megawatts in unusual places

Megawatt charging is not only needed at motorway charging parks. Ports, mines, depots and construction sites need it too, often with insufficient grid connections, with battery buffers or DC grids as the source, and in harsh environments.

Standard charging modules of 30 to 60 kW have to be combined by the dozen for this. Input voltages outside the grid range are not foreseen.

Typical requirements

charging power in the megawatt range

input from grid rectifier, storage or DC grid

galvanic isolation per charge point

vehicle voltages from 400 to over 1000 V

buffer storage to relieve the grid connection

environmental conditions beyond the standard

Our approach

Power stage from 250 kW building blocks

The HPDC modules form the DC/DC stage between DC bus and vehicle. Charging controller, connector and vehicle communication come from the charging station manufacturer.

01

Flexible input

The modules work at 650–750 VDC, optionally at 800 VDC. With a balancer the input reaches 1500 VDC, for example from a battery buffer or DC grid.

02

Isolated per charge point

The resonant converters isolate galvanically. Each charge point gets its own IT system with its own insulation monitoring.

03

Combine power

Modules are connected in series for high voltages and in parallel for high currents. DC contactors assign modules to charge points.

What sets it apart

Why knestronX

Fewer assemblies

250 kW per module instead of many small charging modules.

Special inputs

Input voltages up to 1500 VDC with balancer, for example from storage or DC grids.

Buffer from the same platform

Bidirectional modules connect buffer storage and reduce connection power.

SiC efficiency

Over 98 % per module.

For station manufacturers

Power stage with EtherCAT, CAN and Modbus for integration into your own charging stations.

Harsh environments

For mining and industry there are dedicated solution approaches, see DC charging in harsh environments.

Key data

Specifications at a glance

Parameter Value
Topology balancer + BRW + 2L-TSB
Module KNT ITS SC 1, SiC, bidirectional
Input 650–750 VDC (800 VDC optional); with balancer up to 1500 VDC
Output series up to 1400 VDC / ±350 A, parallel up to approx. 684 VDC / ±700 A per module
Power 250 kW per module, 325 kW for 5 s
Isolation resonant transformer, 5.2 kV AC
Communication EtherCAT, CAN, Modbus
Cooling water; air on request where the installation allows

Building blocks used

BRW galvanic isolation per charge point
TSB control of charging current and voltage
Balancer input up to 1500 VDC
Cabinet DC contactors, insulation monitoring

Fields of use

charging parks for e-trucks and buses ports and ship charging mining and construction machinery depots with buffer storage airport apron and plant traffic

FAQ

Questions from practice

Does knestronX supply complete chargers?

For station manufacturers we supply the power stage. We develop complete charging stations for special environments as projects, for example for mining.

Who handles connector and vehicle communication?

The station manufacturer's charging controller. The HPDC modules receive their setpoints via EtherCAT, CAN or Modbus.

Can storage relieve the grid connection?

Yes. Bidirectional HPDC modules connect a buffer storage to the DC bus. It charges slowly from the grid and delivers high power during charging.

Contact

Let's talk about your application

Tell us charging power, vehicle voltages, input source and voltage, number of charge points and environmental conditions.

KNESTEL Technologie & Elektronik GmbH

Osterwalder Strasse 12
87496 Hopferbach, Germany
Phone +49 8372 708-0
vertrieb@knestel.de

Technical data: status 2026. Subject to change. Design and sizing depend on the individual project.