knestronX · Applications

What you can build with knestronX

Two platforms, one modular system: the Low Power DC platform (LPDC) works between the 230 VAC grid and batteries up to 65 V. The High Power DC platform (HPDC) converts 250 kW per module up to 1400 VDC. These pages show how they become real systems.

LPDC platform

Low Power DC platform

3.6 kW modules for grid, battery and extra-low voltage. For device manufacturers and integrators building their own systems.

Battery inverter for storage from 12 to 65 V

Charge and discharge storage at the 230 VAC grid. At 48 V two DCDs share the power, from 60 V one is enough.

3.6 kW single-phase, 10.8 kW three-phase
View application →

Online UPS with double conversion for servers and equipment rooms

Online UPS with double conversion, battery on the DC link. A DCD supplies 48 V racks directly.

Online double conversion
View application →

More power from a small generator

A small generator plus battery covers load peaks up to 27 kW three-phase.

27 kW from a 5.4 kW generator
View application →

Backup power from the battery, single- or three-phase

When the grid fails, the AFE forms the grid for the backup circuit from the battery, single- or three-phase.

1~ or 3~ grid-forming
View application →

PV storage with DC coupling at extra-low voltage

PV modules charge directly on the 70 VDC bus via a DCD with MPPT, without a detour via the AC grid.

MPPT option for the DCD
View application →

Charge mobile storage at wallboxes and charging stations

The AFE evaluates Control Pilot and Proximity Pilot and charges at a wallbox or public charging station.

CP / PP option for the AFE
View application →

Test battery modules from 12 to 65 V and recover the energy

The DCD charges and discharges battery modules from 12 to 65 V. The energy returns to the grid.

12–65 V devices under test, regeneration
View application →

On-board power with several voltages from one set of modules

Shore power becomes a galvanically isolated on-board grid with battery buffer, one DCD per voltage level.

12 / 24 / 48 V also 28 V, isolated
View application →

Buffered 48 VDC for radio and network equipment

Buffered 48 VDC supply for radio and network equipment, with PV via MPPT even at remote sites.

48 VDC from grid, battery and PV
View application →

Shave load peaks, relieve the grid connection

Storage covers peaks from machines or refrigeration and lowers the demand at the grid connection.

6 / 10 / 16 A AFE input current limitable
View application →

Combine used battery packs into one storage system

Used packs with different voltages each work on their own DCD on the shared 70 VDC bus.

1 DCD per battery pack
View application →

Mobile storage for construction sites and events

The storage charges at a charging station and supplies on site as an island grid, quietly and without exhaust.

CP / PP charge, grid-forming on site
View application →

HPDC platform

High Power DC platform

Bidirectional 250 kW SiC modules, galvanically isolated, connectable in series or parallel. Input 650–750 VDC (800 VDC optional). For test fields, storage, charging and plants.

Charge and discharge battery modules and packs in the test field

Charging and discharging battery modules in the test field, bidirectional and galvanically isolated.

250 kW per module, CONVERT-BAT 250
View application →

Simulate batteries, reproducibly and bidirectionally

Simulation of batteries and drive components, current and voltage fully controllable. Also for fuel cell test systems.

100 kW TEST-SIM 100, 125 kW peak
View application →

Power electronics for megawatt charging and DC fast charging

Megawatt charging and DC fast charging with high voltages through series connection.

250 kW per module, combinable to multi-MW
View application →

Direct current for electrolysers and Power-to-X

DC supply for electrolysis systems with high currents, up to 700 A per module in parallel.

700 A per module in parallel
View application →

Couple storage and DC grids bidirectionally

Bidirectional coupling of storage and DC grids, for example in smart grids.

4Q bidirectional, galvanically isolated
View application →

Rail networks: storage and DC grid stabilisation

Storage and power electronics stabilise DC rail networks, smooth load peaks and absorb braking energy.

up to 1500 V input with balancer
View application →

DC source and sink for hydrogen test fields

Source for electrolysers, sink for fuel cells, in 250 kW steps up to the MW range.

250 kW per module, combinable
View application →

Multi-channel DC supply for drive test benches

Several independently controlled channels up to 1400 V for powertrains, regenerative and controlled via EtherCAT.

< 1 ms current rise
View application →

DC charging where standard chargers reach their limits

Sealed charging station without filter changes for dust, heat and difficult grids, up to the MW range.

150–1000 V charging voltage
View application →

Solar power straight into high-voltage storage

PV strings charge 1500 V storage directly, with MPPT and buck-boost operation.

≥ 98.6 % calculated efficiency
View application →

Controlled direct current up to 1600 A per channel

Controlled direct current up to 1600 A per channel for plating, coating and electrolysis.

1600 A per channel
View application →

Contact

Your application is not listed?

The list grows with every project. Tell us your grid connection, voltages and power. We will tell you which modules fit and where an adaptation is needed.

KNESTEL Technologie & Elektronik GmbH

Osterwalder Strasse 12
87496 Hopferbach, Germany
Phone +49 8372 708-0
vertrieb@knestel.de

Technical data: status 2026. Subject to change. Design and sizing depend on the individual project.