Application · Electrolysis and Power-to-X
Direct current for electrolysers and Power-to-X
An electrolyser is a large DC load. How much hydrogen it produces depends on the current. The HPDC platform supplies stacks with controlled direct current, up to 700 A per module in parallel, galvanically isolated and scalable in 250 kW steps.
Typical topology: balancer + BRW + 2L-TSB. Without balancer the modules work at 650–750 VDC, optionally at 800 VDC.
700 A
per module in parallel
250 kW
per module, up to the MW range
< 0.1 %
ripple of full scale
> 98 %
efficiency per module
The task
Hydrogen is a matter of current
Electrolysers need high currents at voltages of a few hundred volts. Classic thyristor rectifiers are robust but have a poor power factor and high ripple at part load. With renewable power, however, an electrolyser often runs at part load.
When power from PV or a DC grid is used directly, a conversion stage via the AC grid can be dropped. The supply must then handle high DC input voltages.
Typical requirements
high currents per stack
precise current control even at part load
low ripple
galvanic isolation between source and stack
input from grid, PV or DC grid
scaling into the MW range
Our approach
One module per stack, combinable
Each module controls the current of its stack. For large stacks several modules work in parallel, for high stack voltages in series.
Control the current
The TSBs work in current control with a rise time below 1 ms and ripple below 0.1 % of full scale.
Isolated per stack
The BRWs isolate galvanically. Stacks can have their own potentials and run independently.
Directly on DC
With a balancer the modules handle DC inputs up to 1500 VDC, for example from a PV field or DC grid. On the grid, an AFE does the rectification.
What sets it apart
Why knestronX
High currents
700 A per module in parallel, several modules for larger stacks.
Clean supply
Ripple below 0.1 % of full scale.
Part-load capable
Controlled current over the entire operating range.
Redundant
If one module fails, the others keep running.
DC coupling
Input up to 1500 VDC with balancer, without detour via AC.
Measurement with PAM
Precise current and voltage measurement for balancing and control.
Key data
Specifications at a glance
Building blocks used
Fields of use
FAQ
Questions from practice
How much current can the system deliver?
700 A per module in parallel. Several modules give correspondingly more, power grows in 250 kW steps.
Can the electrolyser run directly on PV?
With a balancer the modules handle PV voltages up to 1500 VDC. MPP control is handled by a higher-level controller or an upstream stage, see PV direct coupling.
And for test fields?
For electrolyser and fuel cell test fields with source and sink there is a dedicated application page.
Related applications
DC source and sink for hydrogen test fields
Source for electrolysers, sink for fuel cells, in 250 kW steps up to the MW range.
Solar power straight into high-voltage storage
PV strings charge 1500 V storage directly, with MPPT and buck-boost operation.
Controlled direct current up to 1600 A per channel
Controlled direct current up to 1600 A per channel for plating, coating and electrolysis.
Contact
Let's talk about your application
Tell us stack voltage and current, number of stacks, energy source and desired total power.
KNESTEL Technologie & Elektronik GmbH
Osterwalder Strasse 12
87496 Hopferbach, Germany
Phone +49 8372 708-0
vertrieb@knestel.de
Technical data: status 2026. Subject to change. Design and sizing depend on the individual project.