HPDC platform Status: Engineered on request

Application · Process power

Controlled direct current up to 1600 A per channel

Electroplating, coating, electrolysis and semiconductor processes need high currents at comparatively low voltages, stable for hours and precisely controlled. The HPDC platform offers a high-current version of its buck converter bridge in a water-cooled cabinet for this.

3~ 400 VAC grid
AC/DC infeed
DC link
TSB high current
up to 1600 A
Process bath, reactor, cell

One cabinet per channel with infeed, high-current TSB, DC contactor and water cooling. One operator panel controls up to three channels.

1600 A

per channel

approx. 120 V

output voltage in the example

±3000 A

measuring range with external transducer

32 bit

precision measurement with PAM

The task

The current determines the result

In electroplating and electrochemical processes the result depends on the charge transported: layer thickness, deposition rate, gas volume. Whoever controls and measures the current precisely controls the process. Fluctuations show up as scrap.

Currents are often in the kA range, voltages well below. Classic thyristor rectifiers are robust, but control slowly and produce high ripple.

Typical requirements

currents above 1000 A per channel

voltages up to approx. 120 V

precise current control over long process times

several channels with shared operation

water cooling

safe disconnection of the output

Our approach

High-current channel from the DC/DC modular system

Each channel uses a high-current version of the buck converter bridge. It controls the current directly and works on a DC link supplied from the three-phase grid by AC/DC infeed modules.

01

Control current, not voltage

The TSB works in current control. The setpoint comes from the plant controller, the module keeps it regardless of the load.

02

Measure precisely

Optionally the PAM measures via external current transducers up to ±3000 A with 32-bit resolution and low drift. The measurement can be integrated into the fast control loop.

03

Ready-built cabinet

DC contactor per channel, water cooling circuit, operator panel with controller. One panel serves up to three channels, insulation monitoring is optional.

What sets it apart

Why knestronX

Currents up to 1600 A

One channel per cabinet, water-cooled and compact.

Precise for hours

PAM current measurement with drift below 3 ppm/K and gain error below 0.005 %.

From series parts

High-current version of the proven TSB, infeed and cabinet concept from the platform.

Multi-channel

Several channels with shared operation, each controlled individually.

Open connectivity

EtherCAT in the module, connection to control systems via the plant controller.

Galvanically isolated variants

Where isolation is needed, ITS modules provide isolated channels with up to 700 A per module.

Key data

Specifications at a glance

Parameter Value
Output current up to 1600 A per channel
Output voltage up to approx. 120 V (project-dependent)
Infeed 3~ 400 VAC via AC/DC modules
Control current or voltage control in the module
Measurement optional PAM, current transducers up to ±3000 A
Switchgear DC contactor 1600 A per channel
Cooling water
Operation panel with controller, up to 3 channels per panel

Building blocks used

High-current TSB buck converter bridge, 1600 A version
AC/DC infeed modules on the three-phase grid
PAM precision measurement (optional)
Cabinet DC contactor, cooling, panel

Fields of use

electroplating and surface technology lab and pilot electrolysis coating and semiconductor processes anodising and electropolishing research and process development

FAQ

Questions from practice

Is more than 1600 A possible?

Whether channels can be combined for one process depends on the process and the control concept. We clarify this during engineering.

How precise is the current measurement?

With the PAM: 32-bit delta-sigma converter, drift below 3 ppm/K, offset and gain error below 0.005 %. The current transducers are matched to the measuring range.

Do I need galvanic isolation?

The high-current TSB is not galvanically isolated. If the process must be floating, we use ITS modules with built-in isolation transformer, up to 700 A per module in parallel connection.

Contact

Let's talk about your application

Tell us current and voltage per channel, number of channels, requirements for accuracy and ripple, and the connection to your process control.

KNESTEL Technologie & Elektronik GmbH

Osterwalder Strasse 12
87496 Hopferbach, Germany
Phone +49 8372 708-0
vertrieb@knestel.de

Technical data: status 2026. Subject to change. Design and sizing depend on the individual project.