Application · UPS for data centres
Online UPS with double conversion for servers and equipment rooms
Servers, network equipment and control rooms must not drop out for a moment when the grid fails. The LPDC platform forms an online UPS: the loads always hang on the inverter, the battery always on the DC link. Nothing switches over when the grid fails.
The battery connects to the 380 VDC link via ISO and DCD and is always engaged. Another DCD supplies 48 VDC racks directly.
0
switchover events on grid failure
48 VDC
rack supply directly via DCD
3.6 kW
per string, expandable in parallel
10.8 kW
three-phase with three strings
The task
No switchover, no interruption
Many small UPS units work offline or line-interactive and only switch to battery when the grid fails. For sensitive IT that is a risk. Online UPS with double conversion avoids it, but is usually built as a closed box without room for adaptation.
At the same time the share of equipment with 48 VDC supply is growing. A classic UPS first generates AC for these racks and then rectifies it again.
Typical requirements
uninterrupted supply without switchover
extra-low-voltage battery
48 VDC outputs for racks and network equipment
single- or three-phase outputs
remote monitoring via Modbus
modular expansion
Our approach
Double conversion from standard modules
Two AFEs and one string of ISO and DCD are enough for a single-phase online UPS. Three strings with synchronised AFEs give a three-phase output.
Rectify
The first AFE rectifies the grid to 380 VDC as a PFC rectifier and supplies the DC link.
Form the grid
The second AFE forms the grid for the servers from the DC link. It always runs, even with the grid intact.
Battery engaged
The battery connects to the DC link via ISO and DCD. If the grid fails, it keeps supplying the DC link. The second AFE notices nothing.
What sets it apart
Why knestronX
No switchover
The loads hang permanently on the grid-forming AFE. A grid failure only changes where the DC link draws its energy.
48 V without detour
A DCD supplies 48 VDC racks directly from the extra-low-voltage bus, without inverter and power supply in between.
Extra-low-voltage battery
The battery sits behind the galvanic isolation in the 12 to 65 V range.
Modular, not a black box
Power, battery voltage and outputs are assembled from modules and parameterised.
Monitoring
CAN to the BMS, Modbus for DTU and monitoring.
For integrators
The platform is for manufacturers and integrators building their own UPS systems.
Key data
Specifications at a glance
Building blocks used
Fields of use
FAQ
Questions from practice
What is the difference from backup power?
With backup power, a grid disconnect opens when the grid fails, and only then does the AFE form the grid. With the online UPS the loads always hang on the grid-forming AFE, nothing switches over.
What power is possible?
One string delivers 3.6 kW single-phase, three strings 10.8 kW three-phase. More AFEs per phase increase power.
And for large AI data centres?
There, distribution moves to 800 VDC. The AI data centre page shows how HPDC and LPDC work together.
Related applications
800 VDC in the data centre: from the bus to extra-low voltage
Central 800 VDC bus, storage on the bus, 50 VDC and auxiliary voltages from two platforms.
Backup power from the battery, single- or three-phase
When the grid fails, the AFE forms the grid for the backup circuit from the battery, single- or three-phase.
Buffered 48 VDC for radio and network equipment
Buffered 48 VDC supply for radio and network equipment, with PV via MPPT even at remote sites.
Contact
Let's talk about your application
Tell us power, outputs (230 VAC, 48 VDC), desired bridging time and battery voltage.
KNESTEL Technologie & Elektronik GmbH
Osterwalder Strasse 12
87496 Hopferbach, Germany
Phone +49 8372 708-0
vertrieb@knestel.de
Technical data: status prototype phase. Subject to change. Design and sizing depend on the individual project.