knestronX · Applications
What you can build with knestronX
Two platforms, one modular system: the Low Power DC platform (LPDC) works between the 230 VAC grid and batteries up to 65 V. The High Power DC platform (HPDC) converts 250 kW per module up to 1400 VDC. These pages show how they become real systems.
LPDC platform
Low Power DC platform
3.6 kW modules for grid, battery and extra-low voltage. For device manufacturers and integrators building their own systems.
Battery inverter for storage from 12 to 65 V
Charge and discharge storage at the 230 VAC grid. At 48 V two DCDs share the power, from 60 V one is enough.
Online UPS with double conversion for servers and equipment rooms
Online UPS with double conversion, battery on the DC link. A DCD supplies 48 V racks directly.
More power from a small generator
A small generator plus battery covers load peaks up to 27 kW three-phase.
Backup power from the battery, single- or three-phase
When the grid fails, the AFE forms the grid for the backup circuit from the battery, single- or three-phase.
PV storage with DC coupling at extra-low voltage
PV modules charge directly on the 70 VDC bus via a DCD with MPPT, without a detour via the AC grid.
Charge mobile storage at wallboxes and charging stations
The AFE evaluates Control Pilot and Proximity Pilot and charges at a wallbox or public charging station.
Test battery modules from 12 to 65 V and recover the energy
The DCD charges and discharges battery modules from 12 to 65 V. The energy returns to the grid.
On-board power with several voltages from one set of modules
Shore power becomes a galvanically isolated on-board grid with battery buffer, one DCD per voltage level.
Buffered 48 VDC for radio and network equipment
Buffered 48 VDC supply for radio and network equipment, with PV via MPPT even at remote sites.
Shave load peaks, relieve the grid connection
Storage covers peaks from machines or refrigeration and lowers the demand at the grid connection.
Combine used battery packs into one storage system
Used packs with different voltages each work on their own DCD on the shared 70 VDC bus.
Mobile storage for construction sites and events
The storage charges at a charging station and supplies on site as an island grid, quietly and without exhaust.
HPDC platform
High Power DC platform
Bidirectional 250 kW SiC modules, galvanically isolated, connectable in series or parallel. Input 650–750 VDC (800 VDC optional). For test fields, storage, charging and plants.
Charge and discharge battery modules and packs in the test field
Charging and discharging battery modules in the test field, bidirectional and galvanically isolated.
Simulate batteries, reproducibly and bidirectionally
Simulation of batteries and drive components, current and voltage fully controllable. Also for fuel cell test systems.
Power electronics for megawatt charging and DC fast charging
Megawatt charging and DC fast charging with high voltages through series connection.
Direct current for electrolysers and Power-to-X
DC supply for electrolysis systems with high currents, up to 700 A per module in parallel.
Couple storage and DC grids bidirectionally
Bidirectional coupling of storage and DC grids, for example in smart grids.
Rail networks: storage and DC grid stabilisation
Storage and power electronics stabilise DC rail networks, smooth load peaks and absorb braking energy.
DC source and sink for hydrogen test fields
Source for electrolysers, sink for fuel cells, in 250 kW steps up to the MW range.
Multi-channel DC supply for drive test benches
Several independently controlled channels up to 1400 V for powertrains, regenerative and controlled via EtherCAT.
DC charging where standard chargers reach their limits
Sealed charging station without filter changes for dust, heat and difficult grids, up to the MW range.
Solar power straight into high-voltage storage
PV strings charge 1500 V storage directly, with MPPT and buck-boost operation.
Controlled direct current up to 1600 A per channel
Controlled direct current up to 1600 A per channel for plating, coating and electrolysis.
HPDC + LPDC
Both platforms combined
When a system spans high voltage down to extra-low voltage, the two platforms share the work.
Contact
Your application is not listed?
The list grows with every project. Tell us your grid connection, voltages and power. We will tell you which modules fit and where an adaptation is needed.